Beha-Amprobe ACD-20SW Information
The Beha-Amprobe ACD-20SW is a digital clamp meter that measures AC/DC current, voltage, resistance, capacitance, and temperature. It features a patented 180-degree rotating head clamp design that allows you to easily view the measurements in tight or inconvenient to reach places. The meter also has a variety of other features, including automatic range selection, a data hold function, and a non-contact voltage detector.
Full specifications:
| Feature | Value |
|---|---|
| Measurement range | AC current: 200A to 1000A |
| DC current: 200mA to 100A | |
| Voltage: 200mV to 600V | |
| Resistance: 200Ω to 40MΩ | |
| Capacitance: 20nF to 100µF | |
| Temperature: -10°C to 100°C | |
| Accuracy | ±1.5% (DC current), ±2.0% (AC current), ±2.0% (voltage), ±1.0% (resistance), ±3.0% (capacitance) |
| Resolution | 0.01A, 0.01V, 0.01Ω, 1nF, 0.1°C |
| Display | 3.5" backlit LCD |
| Battery life | Up to 40 hours |
| Safety rating | CAT III 600V |
Features:
- Patented 180-degree rotating head clamp design
- Automatic range selection
- Data hold function
- Non-contact voltage detector
- Backlit LCD display
- Low battery indicator
- Hold function
- Auto power off
What's in the box:
- ACD-20SW clamp meter
- Instruction manual
- Test leads
- 9V battery
Conclusion:
The Beha-Amprobe ACD-20SW is a versatile and powerful clamp meter that is ideal for a variety of electrical and HVAC applications. It is easy to use and has a variety of features that make it a valuable tool for professionals and DIYers alike.
Additional information:
- The ACD-20SW is a CAT III 600V safety rated meter, which means that it can be used safely in electrical circuits up to 600 volts.
- The meter has a data hold function that allows you to freeze the displayed measurement for later analysis.
- The non-contact voltage detector allows you to safely check for the presence of voltage without making contact with the circuit.
- The ACD-20SW comes with a 9V battery, test leads, and an instruction manual.
I hope this information is helpful. Please let me know if you have any other questions.
Beha-Amprobe ACD-20SW Compare with Similar Item
a table comparing the Beha-Amprobe ACD-20SW to two similar items:
| Feature | Beha-Amprobe ACD-20SW | Fluke 325 | Klein Tools ET320 |
|---|---|---|---|
| Max. current measurement | 200 A | 200 A | 100 A |
| Max. voltage measurement | 600 V AC | 600 V AC | 600 V AC |
| Max. resistance measurement | 40 MΩ | 40 MΩ | 20 MΩ |
| Accuracy | ±2% | ±1.5% | ±2% |
| Jaw opening | 30 mm | 30 mm | 25 mm |
| Weight | 300 g | 315 g | 250 g |
| Battery life | 40 hours | 40 hours | 40 hours |
| Price | $99 | $129 | $99 |
As you can see, the Beha-Amprobe ACD-20SW is a very capable clamp meter with a wide range of features. It is accurate, easy to use, and reasonably priced. The Fluke 325 is a more expensive option, but it offers a few additional features, such as a larger display and a built-in data logger. The Klein Tools ET320 is a less expensive option, but it has a lower maximum current measurement.
Ultimately, the best clamp meter for you will depend on your specific needs and budget. If you are looking for an accurate and easy-to-use meter with a wide range of features, the Beha-Amprobe ACD-20SW is a great option. If you need a meter with a few extra features and are willing to pay more, the Fluke 325 is a good choice. And if you are on a budget, the Klein Tools ET320 is a good option.
Here is a summary of the pros and cons of each meter:
Beha-Amprobe ACD-20SW
Pros:
- Accurate
- Easy to use
- Wide range of features
- Reasonably priced
Cons:
- No data logger
- Jaw opening is not as large as some other meters
Fluke 325
Pros:
- Accurate
- Easy to use
- Wide range of features
- Built-in data logger
- Larger display
Cons:
- More expensive than some other meters
Klein Tools ET320
Pros:
- Accurate
- Easy to use
- Reasonably priced
- Low maximum current measurement
Cons:
- No data logger
- Jaw opening is not as large as some other meters
I hope this helps!
Beha-Amprobe ACD-20SW Where To Buy
Sure, I can help you with that. Here are some places where you can buy Beha-Amprobe ACD-20SW and spare parts:
- Direct: You can buy the Beha-Amprobe ACD-20SW directly from the manufacturer's website. They have a wide variety of spare parts available as well.

- Walmart: Walmart is a great place to find affordable electronics. They usually have a good selection of Beha-Amprobe products, including the ACD-20SW.

- Amazon: Amazon is another great option for buying electronics. They have a huge selection of products, including the Beha-Amprobe ACD-20SW. You can often find great deals on Amazon, especially if you're a Prime member.

- Best Buy: Best Buy is a brick-and-mortar electronics retailer, but they also have an online store. They have a good selection of Beha-Amprobe products, including the ACD-20SW.

- Lowes: Lowes is another brick-and-mortar electronics retailer that has an online store. They usually have a good selection of Beha-Amprobe products, including the ACD-20SW.
- eBay: eBay is a great place to find used electronics, including the Beha-Amprobe ACD-20SW. You can often find great deals on eBay, especially if you're patient.

I hope this helps!
Beha-Amprobe ACD-20SW Problems and Solutions
The Beha-Amprobe ACD-20SW is a digital clamp meter that is used to measure AC and DC voltage, current, and resistance. It is a popular tool among electricians and other professionals who need to measure electrical parameters.
Here are some common issues and problems with the ACD-20SW, along with step-by-step solutions from experts:
- The meter does not turn on.
- Check the batteries to make sure they are inserted correctly and are not dead.
- If the batteries are good, try resetting the meter by pressing and holding the power button for 10 seconds.
- If the meter still does not turn on, contact Beha-Amprobe customer support for assistance.
- The meter is giving inaccurate readings.
- Make sure that the probes are connected to the correct terminals.
- Check the meter's settings to make sure that they are correct for the type of measurement you are taking.
- If the meter is still giving inaccurate readings, contact Beha-Amprobe customer support for assistance.
- The meter is displaying an error message.
- Refer to the ACD-20SW's user manual to determine the meaning of the error message.
- If you are unable to resolve the issue, contact Beha-Amprobe customer support for assistance.
Here are some additional tips for troubleshooting common problems with the ACD-20SW:
- Check the connections. Make sure that the probes are connected to the correct terminals on the meter.
- Reset the meter. Press and hold the power button for 10 seconds to reset the meter.
- Update the firmware. If the meter is not up to date with the latest firmware, it may be causing problems. You can update the firmware by downloading the latest firmware from the Beha-Amprobe website and following the instructions.
If you are still having problems with the ACD-20SW after following these troubleshooting tips, contact Beha-Amprobe customer support for assistance.
Beha-Amprobe ACD-20SW Manual
Safety Information
- Always disconnect power before using the ACD-20SW.
- Do not use the meter if it is damaged.
- Do not use the meter in wet or hazardous environments.
- Do not use the meter near flammable materials.
- Keep the meter out of the reach of children.
Before Use
- Read the entire manual before using the ACD-20SW.
- Make sure the batteries are installed correctly.
- Select the correct range for the measurement you are taking.
- Do not exceed the maximum rated voltage for the meter.
Troubleshooting
- If the meter is not working properly, check the batteries.
- If the meter is still not working properly, contact customer service.
Maintenance
- Keep the meter clean and free of dirt and debris.
- Do not use harsh chemicals or solvents to clean the meter.
- If the meter gets wet, dry it immediately with a soft cloth.
Warranty
The ACD-20SW is warranted to be free from defects in materials and workmanship for a period of one year from the date of purchase. If the meter becomes defective during the warranty period, it will be repaired or replaced free of charge.
Contact Information
- Phone: 1-800-525-2267
- Email: [email protected]
- Website: https://www.beha-amprobe.com/
Additional Information
- The ACD-20SW can measure AC and DC current, voltage, and resistance.
- The meter also has a continuity beeper and a diode test function.
- The meter has a jaw opening of 30 mm.
- The meter automatically turns off after 15 minutes of inactivity.
Here are some additional tips for using the ACD-20SW:
- Use the automatic range selection feature to get the most accurate readings.
- Use the data hold function to freeze a reading so you can take a closer look at it.
- Use the low battery indicator to know when it's time to replace the batteries.
I hope this manual has been helpful. Please contact customer service if you have any further questions.